, Précision d'estimation du vecteur de Stokes complet en présence de bruits de mesure

. .. Choix-d'un-critère-d'optimisation, , p.71

, Optimisation de la mesure du vecteur de Stokes complet en deux acquisitions

, Utilisation de la redondance des mesures pour augmenter la résolution spatiale

, 3.2 Augmentation de la résolution spatiale sur des images simulées, p.79

. .. Utiliser-la-résolution-complète-de-la-caméra-dofp,

.. .. Conclusion,

F. Goudail, M. Boffety, and S. Roussel, Optimal configuration of static Mueller imagers for target detection, Journal of the Optical Society of America A, vol.34, issue.6, p.1054, 2017.
URL : https://hal.archives-ouvertes.fr/hal-01530166

S. Roussel, M. Boffety, and F. Goudail, Polarimetric precision of micropolarizer grid-based camera in the presence of additive and Poisson shot noise, Optics Express, vol.26, issue.23, p.29968, 2018.
URL : https://hal.archives-ouvertes.fr/hal-01932640

S. Roussel, M. Boffety, and F. Goudail, On the optimal ways to perform full Stokes measurements with a linear division-of-focal-plane polarimetric imager and a retarder, Optics Letters, vol.44, issue.11, p.2927, 2019.
URL : https://hal.archives-ouvertes.fr/hal-02468944

X. Li, H. Hu, M. Boffety, S. Roussel, T. Liu et al., Optimal tradeoff between precision and sampling ratein DoFP imaging polarimeters, Optics Letters, issue.23, p.44, 2019.

F. Goudail, X. Li, M. Boffety, S. Roussel, T. Liu et al., Precision of retardance autocalibration infull-Stokes division-of-focal-plane imagingpolarimeters, Optics Letters, issue.22, p.44, 2019.

F. Conférence-internationale, M. Goudail, S. Boffety, and . Roussel, Polarimetric target detection : static vs. active imagers, fundamental limits, 8th International Symposium on Optronics in Defence and Security, 2018.

C. Française, S. Roussel, M. Boffety, and F. Goudail, Performance d'une caméra polarimétriqueà division de plan focal pour l'estimation du vecteur de Stokes linéaire, journée "Traitement des signaux polarimétriques optiques et radar

. Bibliographie,

E. Bartholin, An accompt of sundry experiments made and communicated by that learn'd Mathematician, Dr. Erasmus Bartholin, upon a Chrystal-like Body, sent to him out of Island, Philosophical transactions, vol.5, issue.67, p.1670

C. Roslund and C. Beckman, Disputing Viking navigation by polarized skylight, Applied Optics, vol.33, issue.21, p.4754, 1994.

J. S. Tyo, M. P. Rowe, E. N. Pugh, J. , and N. Engheta, Target detection in optically scattering media by polarization-difference imaging, Applied Optics, vol.35, issue.11, p.1855, 1996.

F. Goudail, Optimization of the contrast in active Stokes images, Optics letters, vol.34, issue.2, pp.121-124, 2009.
URL : https://hal.archives-ouvertes.fr/hal-00746770

G. Anna, F. Goudail, and D. Dolfi, General state contrast imaging : an optimized polarimetric imaging modality insensitive to spatial intensity fluctuations, Journal of the Optical Society of America A, vol.29, issue.6, pp.892-900, 2012.
URL : https://hal.archives-ouvertes.fr/hal-00747189

N. Vannier, F. Goudail, C. Plassart, M. Boffety, P. Feneyrou et al., Active polarimetric imager with near infrared laser illumination for adaptive contrast optimization, Applied Optics, vol.54, issue.25, pp.7622-7631, 2015.
URL : https://hal.archives-ouvertes.fr/hal-01233686

N. Vannier, F. Goudail, C. Plassart, M. Boffety, P. Feneyrou et al., Comparison of different active polarimetric imaging modes for target detection in outdoor environment, Appl. Opt, vol.55, issue.11, pp.2881-2891, 2016.
URL : https://hal.archives-ouvertes.fr/hal-01340278

F. Goudail and M. Boffety, Optimal configuration of static polarization imagers for target detection : erratum, Journal of the Optical Society of America A, vol.33, issue.9, p.1812, 2016.

J. Qi, C. He, and D. S. Elson, Real time complete Stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging, vol.8, pp.317-323, 2017.

S. Shibata, N. Hagen, and Y. Otani, Robust full Stokes imaging polarimeter with dynamic calibration, Optics Letters, vol.44, issue.4, p.891, 2019.

. Andrey-s-alenin, J. Israel, J. Vaughn, and . Scott-tyo, Optimal bandwidth and systematic error of full-Stokes micropolarizer arrays, Applied Optics, vol.57, issue.9, p.2327, 2018.

G. Anna, Optimisation du contraste dans les images polarimétriques :étude théorique, algorithmes et validation expérimentale, 2013.

G. Anna and F. Goudail, Optimal Mueller matrix estimation in the presence of Poisson shot noise, Optics Express, vol.20, issue.19, pp.21331-21340, 2012.
URL : https://hal.archives-ouvertes.fr/hal-00747225

C. S. Chun, F. D. Torok, and E. , Polarization-sensitive, thermal imaging, Proc. SPIE, vol.2234, pp.275-286, 1994.

Z. Yu, P. Deshpande, W. Wu, J. Wang, and S. Y. Chou, Reflective polarizer based on a stacked double-layer subwavelength metal grating structure fabricated using nanoimprint lithography, Applied Physics Letters, vol.77, issue.7, pp.927-929, 2000.

Y. Ekinci, H. Harun, C. Solak, H. David, and . Sigg, Bilayer Al wire-grids as broadband and high-performance polarizers, Optics Express, vol.14, issue.6, p.2323, 2006.

M. Yu, L. Cao, L. Li, L. Dong, L. Wang et al., Fabrication of division-of-focal-plane polarizer arrays by electron beam lithography, Conference Program Digest -7th International Conference on Manipulation, Manufacturing and Measurement on the Nanoscale, pp.79-82, 2017.

S. , B. Powell, and V. Gruev, Calibration methods for division-of-focal-plane polarimeters, Optics Express, vol.21, issue.18, p.21039, 2013.

, Sony Polarization Image Sensor Technology

M. Bradley, J. K. Ratliff, M. P. Boger, J. Fetrow, W. T. Scott-tyo et al., Image processing methods to compensate for IFOV errors in microgrid imaging polarimeters. Polarization : Measurement, Analysis, and Remote Sensing VII, vol.6240, p.62400, 2006.

M. Bradley, J. S. Ratliff, J. K. Tyo, W. T. Boger, D. M. Black et al., Mitigation of image artifacts in LWIR microgrid polarimeter images. Polarization Science and Remote Sensing III, vol.6682, p.668209, 2007.

M. Bradley, C. F. Ratliff, . Lacasse, and . Scott-tyo, Interpolation strategies for reducing IFOV artifacts in microgrid polarimeter imagery, Optics express, vol.17, issue.11, pp.9112-9125, 2009.

S. Gao and V. Gruev, Bilinear and bicubic interpolation methods for division of focal plane polarimeters, Optics Express, p.26161, 2011.

C. F. Scott-tyo, B. Lacasse, and . Ratliff, Total elimination of sampling errors in polarization imagery obtained with integrated microgrid polarimeters, Optics Letters, vol.34, issue.20, pp.3187-3189, 2009.

A. Shfaq, A. Hmed, Z. Iaojin, . Hao, G. Iktor et al., Residual interpolation for division of focal plane polarization image sensors, Optics Express, vol.25, issue.9, pp.1427-1434, 2017.

C. Russell, D. A. Hardie, B. M. Lemaster, and . Ratliff, Super-resolution for imagery from integrated microgrid polarimeters, Optics Express, vol.19, issue.14, p.12937, 2011.

N. Li, Y. Zhao, Q. Pan, and S. G. Kong, Demosaicking DoFP images using Newton's polynomial interpolation and polarization difference model, Optics Express, vol.27, issue.2, p.1376, 2019.

X. Zeng, Y. Luo, X. Zhao, and W. Ye, An end-to-end fullyconvolutional neural network for division of focal plane sensors to reconstruct S0, DoLP, and AoP, Optics Express, vol.27, issue.6, p.8566, 2019.

X. Zhao, A. Bermak, F. Boussaid, and V. G. Chigrinov, Liquidcrystal micropolarimeter array for visible linear and circular polarization imaging, ISCAS 2010 -2010 IEEE International Symposium on Circuits and Systems : Nano-Bio Circuit Fabrics and Systems, vol.18, pp.637-640, 2010.

K. A. Bachman, J. J. Peltzer, P. D. Flammer, T. E. Furtak, R. T. Collins et al., Spiral plasmonic nanoantennas as circular polarization transmission filters, Optics Express, vol.20, issue.2, p.1308, 2012.

J. J. Peltzer, K. A. Bachman, J. W. Rose, P. D. Flammer, T. E. Furtak et al., Plasmonic micropolarizers for full Stokes vector imaging. Polarization : Measurement, Analysis, and Remote Sensing X, vol.8364, pp.83640-83640, 2012.

G. Myhre, W. Hsu, A. Peinado, C. Lacasse, N. Brock et al., Liquid crystal polymer full-stokes division of focal plane polarimeter, Optics Express, vol.20, issue.25, p.27393, 2012.

W. Hsu, G. Myhre, K. Balakrishnan, N. Brock, M. Ibn-elhaj et al., Full-Stokes imaging polarimeter using an array of elliptical polarizer, Optics Express, vol.22, issue.3, p.3063, 2014.

J. Israel, A. S. Vaughn, J. Alenin, and . Scott-tyo, A fast Stokes polarimeter : preliminary design. Polarization Science and Remote Sensing VIII, vol.01, p.1, 2017.

F. Goudail and M. Boffety, Fundamental limits of target detection performance in passive polarization imaging, Journal of the Optical Society of America a-Optics Image Science and Vision, vol.34, issue.4, pp.506-512, 2017.
URL : https://hal.archives-ouvertes.fr/hal-01529362

G. Anna, F. Goudail, P. Chavel, and D. Dolfi, On the influence of noise statistics on polarimetric contrast optimization, Applied Optics, vol.51, issue.8, pp.1178-87, 2012.
URL : https://hal.archives-ouvertes.fr/hal-00747167

F. Goudail and M. Boffety, Optimal configuration of static polarization imagers for target detection, Journal of the Optical Society of America A : Optics and Image Science, and Vision, vol.33, issue.1, pp.9-16, 2016.
URL : https://hal.archives-ouvertes.fr/hal-01299547

F. Goudail, P. Réfrégier, and G. Delyon, Bhattacharyya distance as a contrast parameter for statistical processing of noisy optical images, Journal of the Optical Society of America A, vol.21, issue.7, p.1231, 2004.

A. N. Langvillea and W. J. Stewart, The kronecker product and stochastic automata networks, J. Comp. Appl. Math, vol.167, pp.429-447, 2004.

R. M. Azzam, I. M. Elminyawi, and A. M. El-saba, General analysis and optimization of the four-detector polarimeter, J. Opt. Soc. Am. A, vol.5, pp.681-689, 1988.

J. S. Tyo, Design of optimal polarimeters : maximization of the signal-to-noise ratio and minimization of systematic error, Appl. Opt, vol.41, issue.4, pp.619-630, 2002.

S. N. Savenkov, Optimization and structuring of the instrument matrix for polarimetric measurements, Opt. Eng, vol.41, pp.965-972, 2002.

J. Zallat, S. Ainouz, and M. P. Stoll, Optimal configurations for imaging polarimeters : impact of image noise and systematic errors, J. Opt. A, vol.8, pp.807-814, 2006.
URL : https://hal.archives-ouvertes.fr/hal-00443671

F. , Noise minimization and equalization for stokes polarimeters in the presence of signal-dependent poisson shot noise, Opt. Lett, vol.34, pp.647-649, 2009.

G. Anna and F. Goudail, Optimal mueller matrix estimation in the presence of poisson shot noise, Opt. Express, vol.20, pp.21331-21340, 2012.
URL : https://hal.archives-ouvertes.fr/hal-00747225

N. J. Sloane and R. H. Hardin, Tables of spherical codes with icosahedral symmetry, 1994.

X. Zhao, A. Bermak, F. Boussaid, and V. G. Chigrinov, Liquidcrystal micropolarimeter array for full Stokes polarization imaging invisible spectrum, Optics Express, vol.18, issue.17, pp.17776-17787, 2010.

W. Hsu, G. Myhre, K. Balakrishnan, N. Brock, M. Ibn-elhaj et al., Full-Stokes imaging polarimeter using an array of elliptical polarizer, Optics Express, vol.22, issue.3, p.3063, 2014.

M. Gecevi?ius, M. Beresna, and P. G. Kazansky, Polarization sensitive camera by femtosecond laser nanostructuring, Optics Letters, vol.38, issue.20, p.4096, 2013.

B. Feng, Z. Shi, H. Liu, L. Liu, Y. Zhao et al., Polarized-pixel performance model for DoFP polarimeter, Journal of Optics (United Kingdom), vol.20, issue.6, 2018.

Z. Chen, X. Wang, and R. Liang, Calibration method of microgrid polarimeters with image interpolation, Applied Optics, vol.54, issue.5, pp.995-1001, 2015.

H. Fei, F. Li, W. Chen, R. Zhang, and C. Chen, Calibration method for division of focal plane polarimeters, Appl. Opt, vol.57, issue.18, pp.4992-4996, 2018.

J. Neal, . Brock, T. Bradley, J. E. Kimbrough, and . Millerd, A pixelated micropolarizer-based camera for instantaneous interferometric measurements. Proceedings of SPIE, vol.8160, pp.81600-81609, 2011.

F. Goudail and . Bénière, Estimation of the degree of linear polarization and of the angle of polariztion in the presence of different sources of noise, Appl. Opt, vol.49, issue.4, pp.683-693, 2010.

M. Unser and M. Eden, Maximum likelihood estimation of linear signal parameters for Poisson processes, IEEE Trans. Acoustics, Speech and Signal Processing, vol.36, pp.942-945, 1988.

D. S. Sabatke, M. R. Descour, E. L. Dereniak, W. C. Sweatt, S. A. Kemme et al., Optimization of retardance for a complete stokes polarimeter, Opt. Lett, vol.25, issue.11, pp.802-804, 2000.

A. Papoulis, Probability, random variables and stochastic processes, Mc Graw-Hill, 1991.

J. S. Tyo, Noise equalization in stokes parameter images obtained by use of variableretardance polarimeters, Opt. Lett, vol.25, issue.16, pp.1198-1200, 2000.

M. Foreman and F. Goudail, On the equivalence of optimization metrics in Stokes polarimetry, Opt. Eng, vol.58, p.82410, 2019.

S. Roussel, M. Boffety, and F. Goudail, Polarimetric precision of micropolarizer grid-based camera in the presence of additive and poisson shot noise, Optics express, vol.26, issue.23, pp.29968-29982, 2018.
URL : https://hal.archives-ouvertes.fr/hal-01932640

F. Goudail, Equalized estimation of stokes parameters in the presence of poisson noise for any number of polarization analysis states, Opt. Lett, vol.41, issue.24, pp.5772-5775, 2016.
URL : https://hal.archives-ouvertes.fr/hal-01714000

Y. Mimura, A construction of spherical 2-design, Graphs and Combinatorics, vol.6, issue.4, pp.369-372, 1990.

R. H. Hardin and N. J. Sloane, New spherical designs in three and four dimensions, IEEE International Symposium on Information Theory -Proceedings, vol.441, p.181, 1995.

M. R. Foreman, A. Favaro, and . Aiello, Optimal frames for polarization state reconstruction, Physical Review Letters, vol.115, issue.26, p.263901, 2015.

S. Shibata, N. Hagen, and Y. Otani, Robust full Stokes imaging polarimeter with dynamic calibration, Optics Letters, vol.44, pp.891-894, 2019.

B. M. Ratliff, C. F. Lacasse, and J. S. Tyo, Interpolation strategies for reducing ifov artifacts in microgrid polarimeter imagery, Opt. Express, vol.17, pp.9112-9125, 2009.

S. Gao and V. Gruev, Gradient-based interpolation method for division-of-focal-plane polarimeters, Opt. Express, vol.21, pp.1137-1151, 2013.

J. Zhang, H. Luo, B. Hui, and Z. Chang, Image interpolation for division of focal plane polarimeters with intensity correlation, Opt. Express, vol.24, pp.20799-20807, 2016.

N. Li, Y. Zhao, Q. Pan, and S. G. Kong, Demosaicking dofp images using Newton's polynomial interpolation and polarization difference model, Opt. Express, vol.27, pp.1376-1391, 2019.

J. Kennedy and R. Eberhart, Particle Swarm Optimization, Proceedings of the IEEE International Conference on Neural Networks, pp.1942-1948, 1995.

D. S. Sabatke, M. R. Descour, E. L. Dereniak, W. C. Sweatt, S. A. Kemme et al., Optimization of retardance for a complete Stokes polarimeter, Optics Letters, vol.25, issue.11, p.802, 2000.