D. R. Bickers, The burden of skin diseases in 2004: a joint project of the American Academy of Dermatology Association and the Society for Investigative Dermatology, J. Am. Acad Dermatol, vol.55, p.490, 2006.

Z. Apalla, Epidemiological trends in skin cancer, Dermatol. Pract. Concept, vol.7, pp.1-6, 2017.

M. Carthy and M. , US melanoma prevalence has doubled over past 30 years, BMJ, vol.350, p.3074, 2015.

S. R. Fuller, Digital dermoscopic monitoring of atypical nevi in patients at risk for melanoma, Dermatol. Surg, vol.33, p.1198, 2007.

H. Kittler, H. Pehamberger, K. Wolff, and M. Binder, Diagnostic accuracy of dermoscopy, Lancet Oncol, vol.3, p.159, 2002.

N. Woltsche, C. Schwab, and T. Deinlein, Dermoscopy in the era of dermato-oncology: from bed to bench side and retour, Expert Rev. Anticancer Ther, vol.16, pp.531-572, 2016.

A. M. Glazer, D. S. Rigel, R. R. Winkelmann, and A. S. Farberg, Clinical Diagnosis of Skin Cancer: Enhancing Inspection and Early Recognition, Dermatol. Clin, vol.35, pp.409-425, 2017.

N. Kollias and G. N. Stamatas, Optical non-invasive approaches to diagnosis of skin diseases, J. Investig. Dermatol. Symp. Proc, vol.7, pp.64-75, 2002.

C. Fink and H. A. Haenssle, Non-invasive tools for the diagnosis of cutaneous melanoma, Skin Res. Technol, vol.23, pp.261-271, 2017.

G. Pellacani, P. Guitera, C. Longo, M. Avramidis, S. Seidenari et al., The impact of in vivo reflectance confocal microscopy for the diagnostic accuracy of melanoma and equivocal melanocytic lesions, J. Invest. Dermatol, vol.127, pp.2759-2765, 2007.

P. Guitera, G. Pellacani, K. A. Crotty, R. A. Scolyer, L. X. Li et al., The impact of in vivo reflectance confocal microscopy on the diagnostic accuracy of lentigo maligna and equivocal pigmented and nonpigmented macules of the face, J. Invest. Dermatol, vol.130, pp.2080-2091, 2010.

I. Alarcon, C. Carrera, and J. Palou, Impact of in vivo reflectance confocal microscopy on the number needed to treat melanoma in doubtful lesions, Br. J. Dermatol, vol.170, pp.802-808, 2014.

J. Champin, J. L. Perrot, E. Cinotti, B. Labeille, C. Douchet et al., In vivo reflectance confocal microscopy to optimize the spaghetti technique for defining surgical margins of lentigo maligna, Dermatol. Surg. Mar, vol.40, pp.247-256, 2014.

W. R. Zipfel, Nonlinear magic: multiphoton microscopy in the biosciences, Nat. Biotechnol, vol.21, pp.1369-1377, 2003.

K. Koenig, High-resolution multiphoton tomography of human skin with subcellular spatial resolution and picosecond time resolution, J. Biomed. Opt, vol.8, pp.432-439, 2003.

D. Huang, E. A. Swanson, C. P. Lin, J. S. Schuman, W. G. Stinson et al., Optical coherence tomography, Science, vol.254, pp.1178-1181, 1991.
URL : https://hal.archives-ouvertes.fr/tel-01957283

J. Welzel, Optical coherence tomography of the human skin, J. Am. Acad. Dermatol, vol.37, pp.958-963, 1997.

A. Levine, K. Wang, and O. Markowitz, Optical Coherence Tomography in the Diagnosis of Skin Cancer, Dermatol. Clinics, vol.35, pp.465-488, 2017.

J. Welzel, Optical Coherence Tomography in Dermatology: A Review, Skin Res. Technol, vol.7, pp.1-9, 2001.

M. A. Boone, S. Norrenberg, G. B. Jemec, and V. Del-marmol, Imaging of basal cell carcinoma by high-definition optical coherence tomography: histomorphological correlation. A pilot study, Br. J. Dermatol, vol.167, pp.856-864, 2012.

A. J. Coleman, T. J. Richardson, G. Orchard, A. Uddin, M. J. Choi et al., Histological Correlates of Optical Coherence Tomography in Non-Melanoma Skin Cancer, Skin Res. Technol, vol.19, pp.10-19, 2013.

M. Ulrich, V. Braunmuehl, T. Kurzen, H. Dirschka, T. Kellner et al., The Sensitivity and Specificity of Optical Coherence Tomography for the Assisted Diagnosis of Nonpigmented Basal Cell Carcinoma: An Observational Study, Br. J. Dermatol, vol.173, pp.428-435, 2015.

A. Podoleanu and . Gh, Optical coherence tomography, J. Microscopy, vol.247, pp.209-219, 2012.
URL : https://hal.archives-ouvertes.fr/hal-00557342

W. Drexler, U. Morgner, F. Kärtner, C. Pitris, S. Boppart et al., In vivo ultrahighresolution optical coherence tomography, Opt. Lett, vol.24, pp.1221-1223, 1999.

B. Povazay, K. Bizheva, A. Unterhuber, B. Hermann, H. Sattmann et al., Opt. Lett, vol.27, pp.1800-1802, 2002.

Y. Wang, Y. Zhao, J. S. Nelson, Z. Chen, and R. S. Windeler, Ultrahigh-resolution optical coherence tomography by broadband continuum generation from a photonic crystal fiber, Opt. Lett, vol.28, pp.182-184, 2003.

M. A. Choma, M. V. Sarunic, C. Yang, and J. A. Izatt, Sensitivity advantage of swept source and Fourier domain optical coherence tomography, Opt. Express, vol.11, pp.2183-2189, 2003.

Z. Ding, H. Ren, Y. Zhao, J. S. Nelson, and Z. Chen, High-resolution optical coherence tomography over a large depth range with an axicon lens, Opt. Lett, vol.27, pp.243-245, 2002.

R. A. Leitgeb, M. Villiger, A. H. Bachmann, L. Steinmann, and T. Lasser, Extended focus depth for Fourier domain optical coherence microscopy, Opt. Lett, vol.31, pp.2450-2452, 2006.

K. S. Lee and J. P. Rolland, Bessel beam spectral-domain high-resolution optical coherence tomography with microoptic axicon providing extended focusing range, Opt. Lett, vol.33, pp.1696-1698, 2008.

J. Mo, M. De-groot, and J. F. De-boer, Focus-extension by depth-encoded synthetic aperture in Optical Coherence Tomography, Opt. Express, vol.21, pp.10048-10061, 2013.

T. S. Ralston, D. L. Marks, P. S. Carney, and S. A. Boppart, Interferometric synthetic aperture microscopy, Nat. Phys, vol.3, pp.129-134, 2007.

L. Yu, B. Rao, J. Zhang, J. Su, Q. Wang et al., Improved lateral resolution in optical coherence tomography by digital focusing using two-dimensional numerical diffraction method, Opt. Express, vol.15, pp.7634-7641, 2007.

A. Grebenyuk, A. Federici, V. Ryabukho, and A. Dubois, Numerically focused full-field swept-source optical coherence microscopy with low spatial coherence illumination, Appl. Opt, vol.53, pp.1697-1708, 2014.
URL : https://hal.archives-ouvertes.fr/hal-00956673

D. J. Fechtig, A. Kumar, W. Drexler, and R. A. Leitgeb, Full range line-field parallel swept source imaging utilizing digital refocusing, J. Mod. Opt, vol.62, pp.1801-1807, 2015.

S. Liu, J. A. Mulligan, and S. G. Adie, Volumetric optical coherence microscopy with a high space-bandwidth-time product enabled by hybrid adaptive optics, Biomed. Opt. Express, vol.9, pp.3137-3152, 2018.

J. P. Rolland, P. Meemon, S. Murali, K. P. Thompson, and K. S. Lee, Gabor-based fusion technique for Optical Coherence Microscopy, Opt. Express, vol.18, pp.3632-3642, 2010.

J. Holmes and S. Hattersley, Image blending and speckle noise reduction in multi-beam OCT, Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XIII, Proc. of SPIE, vol.7168, p.71681, 2009.

J. M. Schmitt, S. L. Lee, and K. M. Yung, An optical coherence microscope with enhanced resolving power in thick tissue, Opt. Commun, vol.142, pp.203-207, 1997.

B. Qi, P. A. Himmer, M. L. Gordon, V. X. Yang, D. L. Dickensheets et al., Dynamic focus control in highspeed optical coherence tomography based on a microelectromechanical mirror, Opt. Comm, vol.234, pp.443-448, 2004.

V. X. Yang, N. Munce, J. Pekar, M. L. Gordon, S. Lo et al., Micromachined array tip for multifocus fiber-based optical coherence tomography, Opt. Lett, vol.29, pp.1754-1756, 2004.

A. Dubois, O. Levecq, H. Azimani, A. Davis, J. Ogien et al., Line-field confocal time-domain optical coherence tomography with dynamic focusing, Opt. Express, vol.26, pp.33534-33542, 2018.
URL : https://hal.archives-ouvertes.fr/hal-01950735

A. Dubois, L. Vabre, A. C. Boccara, and E. Beaurepaire, High-resolution full-field optical coherence tomography with a Linnik microscope, Appl. Opt, vol.41, pp.805-812, 2002.
URL : https://hal.archives-ouvertes.fr/hal-00627977

A. Dubois, Focus defect and dispersion mismatch in full-field optical coherence microscopy, Appl. Opt, vol.57, pp.142-150, 2017.
URL : https://hal.archives-ouvertes.fr/hal-01521643

A. Dubois, O. Levecq, H. Azimani, D. Siret, A. Barut et al., Line-field confocal optical coherence tomography for high-resolution noninvasive imaging of skin tumors, J. Biomed. Opt, vol.23, p.106007, 2018.
URL : https://hal.archives-ouvertes.fr/hal-01913796

M. A. Boone, M. Suppa, G. Pellacani, A. Marneffe, M. Miyamoto et al., High-definition optical coherence tomography algorithm for discrimination of basal cell carcinoma from clinical BCC imitators and differentiation between common subtypes, 2015.

M. A. Boone, S. Norrenberg, and G. G. Jemec, Imaging of basal cell carcinoma by high-definition optical coherence tomography: histomorphological correlation. A pilot study, The British journal of dermatology, vol.167, pp.856-64, 2012.