D. R. Bickers, The burden of skin diseases: 2004, Journal of the American Academy of Dermatology, vol.55, issue.3, p.490, 2006.
DOI : 10.1016/j.jaad.2006.05.048

Z. Apalla, Epidemiological trends in skin cancer, Dermatology Practical & Conceptual, vol.7, issue.2, pp.1-6, 2017.
DOI : 10.5826/dpc.0702a01

M. Carthy and M. , US melanoma prevalence has doubled over past 30 years, BMJ, vol.350, p.3074, 2015.

S. R. Fuller, Digital dermoscopic monitoring of atypical nevi in patients at risk for melanoma, Dermatol. Surg, vol.33, p.1198, 2007.

H. Kittler, H. Pehamberger, K. Wolff, and M. Binder, Diagnostic accuracy of dermoscopy, The Lancet Oncology, vol.3, issue.3, p.159, 2002.
DOI : 10.1016/S1470-2045(02)00679-4

N. Woltsche, C. Schwab, and T. Deinlein, Dermoscopy in the era of dermato-oncology: from bed to bench side and retour, Expert Review of Anticancer Therapy, vol.6, issue.5, pp.531-572, 2016.
DOI : 10.1111/j.1365-2133.2012.10868.x

A. M. Glazer, D. S. Rigel, R. R. Winkelmann, and A. S. Farberg, Clinical Diagnosis of Skin Cancer, Dermatologic Clinics, vol.35, issue.4, pp.409-425, 2017.
DOI : 10.1016/j.det.2017.06.001

N. Kollias and G. N. Stamatas, Optical Non-Invasive Approaches to Diagnosis of Skin Diseases, Journal of Investigative Dermatology Symposium Proceedings, vol.7, issue.1, pp.64-75, 2002.
DOI : 10.1046/j.1523-1747.2002.19635.x

C. Fink and H. A. Haenssle, Non-invasive tools for the diagnosis of cutaneous melanoma, Skin Research and Technology, vol.47, issue.3, pp.261-271, 2017.
DOI : 10.1016/j.compbiomed.2014.01.008

G. Pellacani, P. Guitera, C. Longo, M. Avramidis, S. Seidenari et al., The Impact of In Vivo Reflectance Confocal Microscopy for the Diagnostic Accuracy of Melanoma and Equivocal Melanocytic Lesions, Journal of Investigative Dermatology, vol.127, issue.12, pp.2759-2765, 2007.
DOI : 10.1038/sj.jid.5700993

P. Guitera, G. Pellacani, K. A. Crotty, R. A. Scolyer, L. X. Li et al., The Impact of In Vivo Reflectance Confocal Microscopy on the Diagnostic Accuracy of Lentigo Maligna and Equivocal Pigmented and Nonpigmented Macules of the Face, Journal of Investigative Dermatology, vol.130, issue.8, pp.2080-2091, 2010.
DOI : 10.1038/jid.2010.84

I. Alarcon, C. Carrera, and J. Palou, reflectance confocal microscopy on the number needed to treat melanoma in doubtful lesions, British Journal of Dermatology, vol.49, issue.4, pp.802-808, 2014.
DOI : 10.1373/49.1.7

J. Champin, J. L. Perrot, E. Cinotti, B. Labeille, C. Douchet et al., In Vivo Reflectance Confocal Microscopy to Optimize the Spaghetti Technique for Defining Surgical Margins of Lentigo Maligna, Dermatologic Surgery, vol.40, issue.3, pp.247-256, 2014.
DOI : 10.1111/dsu.12432

W. R. Zipfel, Nonlinear magic: multiphoton microscopy in the biosciences, Nature Biotechnology, vol.21, issue.11, pp.1369-1377, 2003.
DOI : 10.1038/nbt899

K. Koenig, High-resolution multiphoton tomography of human skin with subcellular spatial resolution and picosecond time resolution, Journal of Biomedical Optics, vol.8, issue.3, pp.432-439, 2003.
DOI : 10.1117/1.1577349

D. Huang, E. A. Swanson, C. P. Lin, J. S. Schuman, W. G. Stinson et al., Optical coherence tomography, Science, vol.254, issue.5035, pp.1178-1181, 1991.
DOI : 10.1126/science.1957169

J. Welzel, Optical coherence tomography of the human skin, Journal of the American Academy of Dermatology, vol.37, issue.6, pp.958-963, 1997.
DOI : 10.1016/S0190-9622(97)70072-0

A. Levine, K. Wang, and O. Markowitz, Optical Coherence Tomography in the Diagnosis of Skin Cancer, Dermatologic Clinics, vol.35, issue.4, pp.465-488, 2017.
DOI : 10.1016/j.det.2017.06.008

J. Welzel, Optical coherence tomography in dermatology: a review, Skin Research and Technology, vol.7, issue.1, pp.1-9, 2001.
DOI : 10.1034/j.1600-0846.2001.007001001.x

M. A. Boone, S. Norrenberg, G. B. Jemec, D. Marmol, and V. , Imaging of basal cell carcinoma by high-definition optical coherence tomography: histomorphological correlation. A pilot study, British Journal of Dermatology, vol.54, issue.Suppl. 2, pp.856-864, 2012.
DOI : 10.1016/B978-1-4377-1788-4.00011-3

A. J. Coleman, T. J. Richardson, G. Orchard, A. Uddin, M. J. Choi et al., Histological correlates of optical coherence tomography in non-melanoma skin cancer, Skin Research and Technology, vol.159, issue.1, pp.10-19, 2013.
DOI : 10.1111/j.1365-2133.2008.08666.x

M. Ulrich, V. Braunmuehl, T. Kurzen, H. Dirschka, T. Kellner et al., The sensitivity and specificity of optical coherence tomography for the assisted diagnosis of nonpigmented basal cell carcinoma: an observational study, British Journal of Dermatology, vol.27, issue.2, pp.428-435, 2015.
DOI : 10.1111/j.1468-3083.2012.04465.x

A. Podoleanu and . Gh, Optical coherence tomography, Journal of Microscopy, vol.7564, issue.11, pp.209-219, 2012.
DOI : 10.1364/OPEX.12.002404

URL : https://hal.archives-ouvertes.fr/hal-00557342

W. Drexler, U. Morgner, F. Kärtner, C. Pitris, S. Boppart et al., In vivo ultrahigh-resolution optical coherence tomography, Optics Letters, vol.24, issue.17, pp.1221-1223, 1999.
DOI : 10.1364/OL.24.001221

B. Povazay, K. Bizheva, A. Unterhuber, B. Hermann, H. Sattmann et al., Submicrometer axial resolution optical coherence tomography, Optics Letters, vol.27, issue.20, p.1800, 2002.
DOI : 10.1364/OL.27.001800

Y. Wang, Y. Zhao, J. S. Nelson, Z. Chen, and R. S. Windeler, Ultrahigh-resolution optical coherence tomography by broadband continuum generation from a photonic crystal fiber, Optics Letters, vol.28, issue.3, p.182, 2003.
DOI : 10.1364/OL.28.000182

M. A. Choma, M. V. Sarunic, C. Yang, and J. A. Izatt, Sensitivity advantage of swept source and Fourier domain optical coherence tomography, Optics Express, vol.11, issue.18, pp.2183-2189, 2003.
DOI : 10.1364/OE.11.002183

Z. Ding, H. Ren, Y. Zhao, J. S. Nelson, and Z. Chen, High-resolution optical coherence tomography over a large depth range with an axicon lens, Optics Letters, vol.27, issue.4, pp.243-245, 2002.
DOI : 10.1364/OL.27.000243

R. A. Leitgeb, M. Villiger, A. H. Bachmann, L. Steinmann, and T. Lasser, Extended focus depth for Fourier domain optical coherence microscopy, Optics Letters, vol.31, issue.16, pp.2450-2452, 2006.
DOI : 10.1364/OL.31.002450

K. S. Lee and J. P. Rolland, Bessel beam spectral-domain high-resolution optical coherence tomography with micro-optic axicon providing extended focusing range, Optics Letters, vol.33, issue.15, pp.1696-1698, 2008.
DOI : 10.1364/OL.33.001696

J. Mo, M. De-groot, and J. F. De-boer, Focus-extension by depth-encoded synthetic aperture in Optical Coherence Tomography, Optics Express, vol.21, issue.8, pp.10048-10061, 2013.
DOI : 10.1364/OE.21.010048

T. S. Ralston, D. L. Marks, P. S. Carney, and S. A. Boppart, Interferometric synthetic aperture microscopy, Nature Physics, vol.42, issue.2, pp.129-134, 2007.
DOI : 10.1364/OPEX.13.006597

L. Yu, B. Rao, J. Zhang, J. Su, Q. Wang et al., Improved lateral resolution in optical coherence tomography by digital focusing using two-dimensional numerical diffraction method, Optics Express, vol.15, issue.12, pp.7634-7641, 2007.
DOI : 10.1364/OE.15.007634

A. Grebenyuk, A. Federici, V. Ryabukho, and A. Dubois, Numerically focused full-field swept-source optical coherence microscopy with low spatial coherence illumination, Applied Optics, vol.53, issue.8, pp.1697-1708, 2014.
DOI : 10.1364/AO.53.001697

URL : https://hal.archives-ouvertes.fr/hal-00956673

R. J. Meemon, P. Murali, S. Thompson, K. P. Lee, and K. S. , Gabor-based fusion technique for Optical Coherence Microscopy, Opt. Express, vol.18, pp.3632-3642, 2010.

J. Holmes and S. Hattersley, Image blending and speckle noise reduction in multi-beam OCT, Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XIII, Proc. of SPIE 7168, p.71681, 2009.

J. M. Schmitt, S. L. Lee, and K. M. Yung, An optical coherence microscope with enhanced resolving power in thick tissue, Optics Communications, vol.142, issue.4-6, pp.203-207, 1997.
DOI : 10.1016/S0030-4018(97)00280-0

B. Qi, P. A. Himmer, M. L. Gordon, V. X. Yang, D. L. Dickensheets et al., Dynamic focus control in high-speed optical coherence tomography based on a microelectromechanical mirror, Optics Communications, vol.232, issue.1-6, pp.443-448, 2004.
DOI : 10.1016/j.optcom.2004.01.015

V. X. Yang, N. Munce, J. Pekar, M. L. Gordon, S. Lo et al., Micromachined array tip for multifocus fiber-based optical coherence tomography, Optics Letters, vol.29, issue.15, pp.1754-1756, 2004.
DOI : 10.1364/OL.29.001754

A. Dubois, L. Vabre, A. C. Boccara, and E. Beaurepaire, High-resolution full-field optical coherence tomography with a Linnik microscope, Applied Optics, vol.41, issue.4, pp.805-812, 2002.
DOI : 10.1364/AO.41.000805

URL : https://hal.archives-ouvertes.fr/hal-00627977

L. Vabre, A. Dubois, and A. C. Boccara, Thermal-light full-field optical coherence tomography, Optics Letters, vol.27, issue.7, pp.530-532, 2002.
DOI : 10.1364/OL.27.000530

URL : https://hal.archives-ouvertes.fr/hal-00627979

A. Dubois, K. Grieve, G. Moneron, R. Lecaque, L. Vabre et al., Ultrahigh-resolution full-field optical coherence tomography, Applied Optics, vol.43, issue.14, pp.2874-2882, 2004.
DOI : 10.1364/AO.43.002874

URL : https://hal.archives-ouvertes.fr/hal-00533151

A. Dubois, G. Moneron, K. Grieve, and A. C. Boccara, Three-dimensional cellular-level imaging using full-field optical coherence tomography, Physics in Medicine and Biology, vol.49, issue.7, pp.1227-1234, 2004.
DOI : 10.1088/0031-9155/49/7/010

URL : https://hal.archives-ouvertes.fr/hal-00627958

A. Dubois, [Handbook of full-field optical coherence microscopy, pp.1-51, 2016.
DOI : 10.1201/9781315364889

URL : https://hal.archives-ouvertes.fr/hal-01758479

A. Dubois, Focus defect and dispersion mismatch in full-field optical coherence microscopy, Applied Optics, vol.56, issue.9, pp.142-150, 2017.
DOI : 10.1364/AO.56.00D142

URL : https://hal.archives-ouvertes.fr/hal-01521643

Y. Chen, S. W. Huang, A. D. Aguirre, and J. G. Fujimoto, High-resolution line-scanning optical coherence microscopy, Optics Letters, vol.32, issue.14, pp.1971-1973, 2007.
DOI : 10.1364/OL.32.001971